Solivia Series 6-12 kVA

The two MPP trackers support symmetrical (50/50 %) and asymmetrical loading (33/67 %) at the DC inputs. The option to use asymmetric loads is a big advantage in installations that contain both east and west roofs.

A high peak efficiency of 98.2 % and a wide input voltage range of 250 V to 1000 V characterize these inverters. 
Full power MPP tracking is available at an input voltage from 350 V to 850 V (for symmetrical loads at the DC inputs).
 The extended operating temperature range (-20 °C to +60 °C) and the IP65 protection degree of the electronic compartment allow installation in harsh environments.

The inverters contain an integrated DC disconnector. A mounting plate and IP65 AC plug are included in the scope of delivery. Via the RS485 communication interface, a monitoring system can be connected.

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Max. current:
Max. number of MPP trackers:

Input load:

7.8 kWp
6.3 kW
250 … 1000 V
315 … 850 V
20 A (10 A per MPP tracker)
Parallel inputs: 1 MPP Tracker
Separate inputs: 2 MPP Trackers
Symmetrical and asymmetrical (33/67 %)

Nominal apparent power:
Voltage range:
Nominal current (per phase):
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

6.0 kVA
3 x 230 / 400 V (± 20 %) + N + PE
8.7 A
50 / 60 Hz
50/60 Hz +- 5%
0.8 cap … 0.8 ind
<3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

98.2 %
-25 … +60 degrees C
-25 … +40 degrees C
-25 .. +70 degrees C
5 … 95 % (non-condensing)
2000m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

620 x 625 x 275 mm
38 kg
Convection with fans
Amphenol C16/3
4 pairs of MultiContact MC4
RS485
Integrated
5″ monochrome graphical LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:
Safety:
Anti-islanding protection / Grid regulation:

IP65 / IP55
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3
IEC62109-1; IEC62109-2; CE compliance
VDE-AR-N 4105: VFR 2013; VFR 2014

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Max. current:
Max. number of MPP trackers:

Input load:

10.0 kWp
8.1 kW
250 … 1000 V
280 … 850 V
30 A (17 A per MPP tracker)
Parallel inputs: 1 MPP Tracker
Separate inputs: 2 MPP Trackers
Symmetrical and asymmetrical (33/67 %)

Nominal apparent power:
Voltage range:
Nominal current (per phase):
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

8.0 kVA
3 x 230 / 400 V (± 20 %) + N + PE
11.6 A
50 / 60 Hz
50/60 Hz +- 5%
0.8 cap … 0.8 ind
<3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

98.2 %
-25 … +60 degrees C
-25 … +40 degrees C
-25 .. +70 degrees C
5 … 95 % (non-condensing)
2000m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

620 x 625 x 275 mm
41 kg
Convection with fans
Amphenol C16/3
4 pairs of MultiContact MC4
RS485
Integrated
5″ monochrome graphical LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:
Safety:
Anti-islanding protection / Grid regulation:

IP65 / IP55
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3
IEC62109-1; IEC62109-2; CE compliance
VDE-AR-N 4105

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Max. current:
Max. number of MPP trackers:

Input load:

13.2 kWp
10.5 kW
250 … 1000 V
350 … 850 V
30 A (20 A per MPP tracker)
Parallel inputs: 1 MPP Tracker
Separate inputs: 2 MPP Trackers
Symmetric (50/50 %) and asymmetric (33/67%)

Nominal apparent power:
Voltage range:
Nominal current (per phase):
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

10.0 kVA
3 x 230 / 400 V (± 20 %) + N + PE
14.5 A
50 / 60 Hz
50/60 Hz +- 5%
0.8 cap … 0.8 ind
<3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

98.3 %
-25 … +60 degrees C
-25 … +40 degrees C
-25 .. +70 degrees C
5 … 95 %
2000m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:

Communication interfaces:
DC disconnector:
Display:

620 x 625 x 275 mm
41 kg
Convection with fans
Amphenol C16-3
4 pairs of MultiContact MC4
2 pairs per MPP tracker
2 x RS485 (RJ45)
Integrated
5″ monochrome graphical LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:
Safety:
Anti-islanding protection / Grid regulation:

IP65 / IP55
I
Yes
Yes
Current limitation; power limitation
IEC 62109-1 / -2; CE compliance
EN 61000-6-2; EN 61000-6-3
CEI 0-21; EN 50438; Synergrid C10/C11 06/2012; UTE C15-712-1; VDE-0126-1-1/A1; VDE-AR-N 4105; VFR 2013; VFR 2014

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Max. current:
Max. number of MPP trackers:
Input load:

15.6 kWp
12.2 kW
250 … 1000 V
420 … 850 V
30 A (20 A per MPP tracker)
Parallel inputs: 1 MPP Tracker
Symmetrical and asymmetrical (33/67%)

Nominal apparent power:
Voltage range:
Nominal current (per phase):
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

12.0 kVA
3 x 230 / 400 V (± 20 %) + N + P
17.4 A
50 / 60 Hz
50/60 Hz +- 5%
0.8 cap … 0.8 ind
<3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

98.3 %
-25 … +60 degrees C
-25 … +40 degrees C
-25 .. +70 degrees C
5 … 95 % (non-condensing)
2000m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

620 x 625 x 275 mm
41 kg
Convection with fans
Amphenol C16/3
4 pairs of Multi-Contact MC4
RS485
Integrated
5″ monochrome graphical LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:
Safety:
Anti-islanding protection / Grid regulation:

IP65 / IP55
I
Yes
Yes
Current limitation; power limitation
IEC62109-1; IEC62109-2; CE compliance
EN 61000-6-2; EN 61000-6-3
VDE-AR-N 4105