Solivia Series 2.0-3.6 kVA

High-efficiency transformer-based string inverters with extended measurements and several functions to set up and control operation behavior.

The combination of transformer-based technology and protection degree IP65 allows these inverters to be used in harsh environments. When PV modules are used that need to be grounded, these inverters are the ideal choice. They not only supports negative and positive grounding, but also offers several monitoring methods.The inverters can be used with input voltages up to 600 V and operating temperatures up to 70 °C. Gradual derating does not start before 55 °C.

The inverters offer an extended MPP tracking function to improve the yield. The comprehensive statistics as well as all messages about the current operating status and the complete life-time operating behavior can be read out on the easy-to-use display.

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Nominal current:
Max. current:

2400 Wp
2200 W
125 … 600 V
150 … 480 V
6.2 A @ 360 V
15 A

Nominal apparent power:
Voltage range:
Nominal current:
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

2000 VA
184 … 276 V
8.7 A
50 Hz
45 … 65 Hz
0.8 cap … 0.8 ind
< 3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

95.8 %
-25 … +70 °C
-25 … +55 °C
-25 … +80 °C
0 … 95 %
2000 m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

418 x 410 x 182 mm
21.5 kg
Convection
Wieland RST25i3S
1 pair of Multi-Contact MC4
2 x RS485 (RJ45) + 1 USB A 2.0
Integrated
3 LEDs, 4-line LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:

Safety:
Anti-islanding protection / Grid regulation:

IP65
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3
IEC62109-1 / -2
VDE 0126-1-1/A1; UTE C15-712-1; Synergrid C10/11 (06/2012); G83/1-2; G59/1-2; VDE-AR-N 4105; VFR 2013; VFR 2014

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Nominal current:
Max. current:

3030 Wp
2750 W
125 … 600 V
150 … 480 V
7.2 A @ 360 V
18.2 A

Nominal apparent power:
Voltage range:
Nominal current:
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

2500 VA
184 … 276 V
10.9 A
50 Hz
45 … 65 Hz
0.8 cap … 0.8 ind
< 3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

96.1 %
-25 … +70 °C
-25 … +55 °C
-25 … +80 °C
0 … 95 %
2000 m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

418 x 410 x 182 mm
21.5 kg
Convection
Wieland RST25i3S
2 pairs of Multi-Contact MC4
2 x RS485 (RJ45) + 1 USB A 2.0
Integrated
3 LEDs, 4-line LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:

Safety:
Anti-islanding protection / Grid regulation:

IP65
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3
IEC62109-1 / -2
VDE 0126-1-1/A1; UTE C15-712-1; France/Islands (60 Hz); RD 661/2007; RD 1699/2011; CEI 0-21; Synergrid C10/11 (06/2012); EN 50438; G83/1-2; G59/1-2; VDE-AR-N 4105; VFR 2013; VFR 2014

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Nominal current:
Max. current:

3700 Wp
3300 W
125 … 600 V
150 … 480 V
9.2 A @ 360 V
22 A

Nominal apparent power:
Voltage range:
Nominal current:
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

3000 VA
184 … 276 V
13.1 A
50 Hz
45 … 65 Hz
0.8 cap … 0.8 ind
< 3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

96.1 %
-25 … +70 °C
-25 … +55 °C
-25 … +80 °C
0 … 95 %
2000 m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

418 x 410 x 182 mm
21.5 kg
Convection
Wieland RST25i3S
2 pair of Multi-Contact MC4
2 x RS485 (RJ45) + 1 USB A 2.0
Integrated
3 LEDs, 4-line LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:

Safety:
Anti-islanding protection / Grid regulation:

IP65
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3
IEC62109-1 / -2
VDE 0126-1-1/A1; UTE C15-712-1; France/Islands (60 Hz); RD 661/2007; RD 1699/2011; CEI0-21; Synergrid C10/11 (06/2012); EN 50438; G83/1-2; G59/1-2; VDE-AR-N 4105; VFR 2013; VFR 2014

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Nominal current:
Max. current:

4000 Wp
3600 W
125 … 600 V
150 … 480 V
10 A @ 360 V
24 A

Nominal apparent power:
Voltage range:
Nominal current:
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

3300 VA
184 … 276 V
8.7 A
50 Hz
45 … 65 Hz
0.8 cap … 0.8 ind
< 3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

96.2 %
-25 … +70 °C
-25 … +55 °C
-25 … +80 °C
0 … 95 %
2000 m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

418 x 410 x 182 mm
21.5 kg
Convection
Wieland RST25i3S
2 pair of Multi-Contact MC4
2 x RS485 (RJ45) + 1 USB A 2.0
Integrated
3 LEDs, 4-line LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:

Safety:
Anti-islanding protection / Grid regulation:

IP65
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3
IEC62109-1 / -2
VDE 0126-1-1/A1; UTE C15-712-1; France/Islands (60 Hz); RD 661/2007; RD 1699/2011; CEI0-21; Synergrid C10/11 (06/2012); EN 50438; G83/1-2; G59/1-2; VDE-AR-N 4105; VFR 2013; VFR 2014

Max. recommended PV power:
Nominal power:
Voltage range:
Full power MPP range:
Nominal current:
Max. current:

4300 Wp
3850 W
125 … 600 V
170 … 480 V
10.7 A @ 360 V
24 A

Nominal apparent power:
Voltage range:
Nominal current:
Nominal frequency:
Frequency range:
Power factor adjustable:
Total harmonic distortion (THD):

3600 VA
184 … 276 V
15.7 A
50 Hz
45 … 65 Hz
0.8 cap … 0.8 ind
< 3 % @ nominal apparent power

Max. efficiency:
Operating temperature:
Full power without derating:
Storage temperature:
Humidity:
Max. operating altitude:

96.2 %
-25 … +70 °C
-25 … +55 °C
-25 … +80 °C
0 … 95 %
2000 m (above sea level)

Size (H x W x D):
Weight:
Cooling:
AC connector:
DC connector:
Communication interfaces:
DC disconnector:
Display:

418 x 410 x 182 mm
21.5 kg
Convection
Wieland RST25i3S
2 pair of Multi-Contact MC4
2 x RS485 (RJ45) + 1 USB A 2.0
Integrated
3 LEDs, 4-line LCD

Protection degree:
Safety class:
Configurable trip parameters:
Insulation monitoring:
Overload behavior:
EMC:

Safety:
Anti-islanding protection / Grid regulation:

IP65
I
Yes
Yes
Current limitation; power limitation
EN61000-6-2; EN61000-6-3; EN61000-3-2; EN61000-3-3
IEC62109-1 / -2
VDE 0126-1-1/A1; UTE C15-712-1; Synergrid C10/11 (06/2012); G83/1-2; G59/1-2; VDE-AR-N 4105; VFR 2013; VFR 2014